entered. Once the bypass command is entered, pressing
[9] recalls the last zone or group of zones which was
bypassed. If the same group of zones is bypassed each
time, this bypass recall feature can be used instead of
having to bypass zones individually.
When the PC2550 is programmed, the ability to bypass
certain zones may be eliminated. In this case, the “Zone”
lights for those zones will not come on in response to the
bypass command. See the “Zone Bypass Mask”
instruction in the [][8] Installer’s programming section. If
the “Bypass” light is on when arming the panel, the [][1]
command should be used to see which zones are
bypassed so that zones are not unintentionally bypassed.
Zone bypasses are automatically cancelled when the
panel is disarmed.
If light 8 in section [16] is on then a code must be entered
with []+[1] to bypass zones. Only the zones assigned to
the same side of the system as the user code can be
bypassed. The ability to bypass using certain access
codes can be eliminated. See the “Access Bypass Mask”
instruction in the [] [8] Installer’s Programming section.
Note: At no time can any armed zone be bypassed.
Trouble Display
[]+[2]
The PC2550 continuously monitors a number of possible
trouble conditions. If one of these conditions occurs, the
keypad “Trouble” indicator will light and the audible
indication will sound (two short beeps every 10 seconds).
When the [#] key is pressed the audible indication will
stop but the “Trouble” indicator light will remain on until
the trouble is cleared. Trouble conditions can also be
transmitted to the monitoring station (see “Programming
Guide” sections [12] and [13] for alarm and restoral
trouble codes). Press the [] then [2] keys to display the
type of trouble. The “Zone” lights indicate the type of
trouble condition.
1 Low stand-by battery
2 AC power failure
3 Day zone trouble
4 Telephone line trouble
5 Unsuccessful communication attempt with monitoring
station
6 Bell circuit failure
7 Smoke detector zone trouble
8 Loss of time on internal clock
Press [#] to return to “Ready”.
1 Low Battery...
A battery trouble will be displayed and
can be reported if the battery is weak, disconnected or
the battery fuse is blown. Only one low battery alarm or
restoral transmission takes place per arming period. Low
battery trouble display is latching and can only be
cleared by battery restoration.
2 AC Power Failure...
There is no audible annunciation
on AC power failure. The system “Trouble” light will come
on but the audible indication will not sound until there is a
low battery condition. Transmission delay can be
programmed for 1 to 99 minutes. See “Programming
Guide” section [20].
3 Day Zone Trouble...
This trouble applies only to zones
which have been programmed as day zones.
(“Programming Guide” section [14]). A day zone creates
a trouble signal when the panel is disarmed and an alarm
signal when the panel is armed.
44
44
4
Telephone Line Trouble...Telephone Line Trouble...
Telephone Line Trouble...Telephone Line Trouble...
Telephone Line Trouble...
A telephone line trouble is
generated when the line voltage drops below 3 volts for
more than 30 seconds. It generates a keypad trouble
when the system is disarmed and rings a local alarm
when the panel is armed. See section [16] for options.
55
55
5
Unsuccessful Communication...Unsuccessful Communication...
Unsuccessful Communication...Unsuccessful Communication...
Unsuccessful Communication...
If the digital
communicator is unsuccessful communicating with the
monitoring station after eight attempts to each phone
number that is to be tried, a trouble is generated. If a
later attempt to communicate is successful the trouble is
cleared. This trouble can also be cleared by pressing the
[#] key to exit the trouble view mode.
66
66
6
Bell Circuit Failure...Bell Circuit Failure...
Bell Circuit Failure...Bell Circuit Failure...
Bell Circuit Failure...
If the bell fuse fails or the bell
circuit is open, a keypad trouble and a trouble
transmission are generated.
77
77
7
Smoke Detector Zone Trouble...Smoke Detector Zone Trouble...
Smoke Detector Zone Trouble...Smoke Detector Zone Trouble...
Smoke Detector Zone Trouble...
If a FIRE zone is open
circuit, a keypad trouble and a trouble transmission are
generated. A trouble on the FIRE zone will unconditionally
initiate an audible indication on the keypad. This means
that even if any other previous trouble has been silenced,
a FIRE zone trouble will restart the keypad buzzer.
88
88
8
Loss of Internal Time...Loss of Internal Time...
Loss of Internal Time...Loss of Internal Time...
Loss of Internal Time...
When the PC2550 is powered
up or reset, the internal time of day clock needs to be set
to the correct time. This trouble is cleared when the
trouble display is viewed and exited or when an attempt
is made to reset the internal time of day clock. See
“[][6] User’s Function Command” for resetting time of
day clock.
If the [9] is pressed while in the trouble display mode the
most recent trouble will be displayed on the zone LEDs.
This trouble memory feature is useful as a diagnostic aid
when installing and servicing the PC2550.
Alarm Memory Display
[]+[3]
Press [] then [3] to enter the alarm memory mode. The
“Memory” light will flash and any alarm caused during the
last armed period will be displayed on the zone lights. In
addition to the last alarm memory there are 2 history
levels. After entering the memory mode (pressing []
then [3]), pressing [9] will cause the keypad to display
the two other levels of alarm history. Each time [9] is
pressed the keypad will beep 1, 2 or 3 times to indicate
which level of history is being viewed. When the panel is
armed, the last alarm memory is cleared and the contents
moves to the 1st history level. The “Memory” light will only
be on when there was an alarm during the last armed
period.
Press [#] to return to “Ready”.
Switched Auxiliary Supply Control
[]+[Hold Down 4]
To interrupt the switched auxiliary power supply press []
then hold down [4] for the desired interrupt time. When