NOTES ON UL INSTALLATION
This equipment is UL Listed in accordance with standard UL1023 (Household Burglar - Alarm
System Units), standard UL985 (Household Fire Warning Units), UL1635 (Digital Alarm
Communicator System Units), standard UL365 (Police Station Connected Burglar Alarm Units
and Systems), standard UL609 (Local Burglar Alarm Units and Systems), and standard UL1610
(Central Station Burglar Alarm Units).
This equipment has the capability of being programmed for operational features that are not
allowed for UL Listed installations. To stay within the standard for household applications, the
installer should use the following guidelines when configuring the system.
1. ALL components of the system should be UL Listed for the intended application. Note
elsewhere in this manual, recommendations for smoke detectors and battery to be used
with this equipment.
2. If this system is configured for “Fire”, the installer should refer to NFPA Standards #74 for
details on locating smoke detectors. When the “Fire” feature is enabled, there must be at
least one UL Listed indoor Fire Alarm Warning Signaling Appliance.
3. Residential fire and burglary systems:
Maximum allowed entry time = 45 seconds
Maximum allowed exit time = 60 seconds
Minimum allowed bell cutoff time = 4 minutes
4. The “Split Arming” feature is not allowed for UL Listed installations. The equipment must be
configured as a single system.
5. User bypass must be enabled so that a user code is required to bypass zones.
6. The installer should caution the user to NOT give system information to casual users. E.g.
Codes, bypass methods, etc. to babysitters or home service people. Only the “One-Time”
use code should be given to the casual user.
7. The installer should advise the user and note in the user manual:
Service organization name and telephone number
The programmed exit time
The programmed entry time
8. Remote programming must be disabled.
9. Grade A Local Mercantile Alarm Unit Installations
Listed Grade A bell Model AMSECO MBL10B and bell housing Model AB-12.
Alarm enclosure Model CMC-1, with door tamper.
Maximum 60 seconds of exit and entrance delays.
Provision is made for bell test upon arming.
Use of integral DACT (Digital Alarm Communicator Transmitter).
10.Grade A Police Station Connected Burglar Alarm Installations
Same as Grade A Local Mercantile Alarm Unit Installations with the following addition:
An audible ringback indication is provided at the keypad to indicate completion of the
closing signal transmission to the digital alarm communicator receiver.
11.Grade B Central Station Alarm Unit Installations
Same as Grade A Local Mercantile Alarm Unit Installations and Grade A Police Station
Connected Burglar Alarm Installations.
12.Grade C Central Station Alarm Unit Installations
Same as Grade B Central Station Alarm Unit Installations with the following exception: the
bell and listed Model CMC-1 alarm housing is not required.
13.Grade A Residential Burglary Warning System
14.Household Fire Warning System
Zobrazit stránku 41
1 2 ... 37 38 39 40 41 42 43 44

Komentáře k této Příručce

Žádné komentáře

Cables Direct B5-100Y manuels

Manuels d'utilisation et guides de l'utilisateur pour Câbles de mise en réseau Cables Direct B5-100Y.
Nous fournissons des manuels en pdf 1 Cables Direct B5-100Y à télécharger gratuitement par type de document : Fiche technique


Table des matières





Plus de produits et de manuels pour Câbles de mise en réseau Cables Direct

Modèles Type de document
URT-600-HR Fiche technique   Cables Direct URT-600-HR networking cable, 1 pages
ERT-601V Fiche technique   Cables Direct ERT-601V networking cable, 1 pages
B6-503K Fiche technique   Cables Direct B6-503K networking cable, 1 pages
B6ST-705K Fiche technique   Cables Direct B6ST-705K networking cable, 1 pages
B5-105G Fiche technique   Cables Direct B5-105G networking cable, 1 pages
URT-600P Fiche technique   Cables Direct URT-600P networking cable, 1 pages
URT-610K Fiche technique   Cables Direct URT-610K networking cable, 1 pages
XXURT-610B Fiche technique   Cables Direct XXURT-610B networking cable, 1 pages
URT-601.5G Fiche technique   Cables Direct URT-601.5G networking cable, 1 pages
URT-601W Fiche technique   Cables Direct URT-601W networking cable, 1 pages
RJEXT-10 Fiche technique   Cables Direct RJEXT-10 networking cable, 1 pages
URT-605W Fiche technique   Cables Direct URT-605W networking cable, 1 pages
B6ST-702R Fiche technique   Cables Direct B6ST-702R networking cable, 1 pages
EXT-602 Fiche technique   Cables Direct EXT-602 networking cable, 1 pages
URT-630 Fiche technique   Cables Direct URT-630 networking cable, 1 pages
ERT-601-5W Fiche technique   Cables Direct ERT-601-5W networking cable, 1 pages
B6-501B Fiche technique   Cables Direct B6-501B networking cable, 1 pages
XXURT-610R Fiche technique   Cables Direct XXURT-610R networking cable, 1 pages
EXT-605 Fiche technique   Cables Direct EXT-605 networking cable, 1 pages
B6-502R Fiche technique   Cables Direct B6-502R networking cable, 1 pages