This output can be used for operating other devices such
as garage door opener, special lighting or door strikes.
The programmable output must be selected for keypad
utility using the [][8][Installer’s Code][30] command and
programming a [2], [3], [4] or [5].
Depending on the option chosen in the programming
section, the programmable output is activated by
pressing the [] then [7] keys followed by a Group A
access code, Group B access code, any access code, or
no code at all. When the proper keys are pressed the
keypad sounder and the programmable output are
activated for 5 seconds.
Installer’s Programming Commands
[]+[8]+[INSTALLER’S CODE]
The PC2550 is completely programmed from the keypad
by using commands in the [] [8] section. The
commands are described in detail in the programming
section of this manual.
At Home” Arming
[]+[9]+[ACCESS CODE]
Entering [], [9] before the arming code, arms the panel
without any entry delay on the delay zones and bypasses
zones that are defined as “Home-Away”. This command
is used for arming the system while at home. When the
panel is armed using [], [9], the “Armed” light will be on
flashing and the bypass light will be on to indicate that
the “Home-Away” zones are bypassed. Once the panel is
armed in this mode, using [], [1] will remove the bypass
from those zones defined as “Home-Away” if they have
NOT
been manually bypassed. The [], [1] command
used here, only removes the bypass from zones that have
been Automatically bypassed with the [], [9]
command.”
“Quick Arm” Command
[]+[0]
Entering [][0] is accepted as a valid arming code when
the “Quick Arm” feature is activated. This command is
often used when individuals are required to arm the
system. These individuals will not be able to disarm the
system. This could be used with home visitors in the case
of a residential alarm or junior employees and
maintenance staff in the case of a commercial alarm.
See instructions in the “[][6] User’s Functions
Command” section for activating the “Quick Arm” feature.
This feature should not be enabled if the One Time Use
Code is enabled. The One Time Use Code must be used
for arming before it is erased.
Quick Exit
[]+[0] When Armed
Entering [] [0] when the system is fully armed will allow
the user 2 minutes to exit the premises through any delay
zone without altering the status of the system if the Quick
Exit feature is enabled. The Quick Exit feature can be
enabled by turning on light 1 in section [18]. After [] [0]
is entered into an armed system, one and only one delay
zone may be tripped. Any additional activity on any other
active zone will cause that zone to begin its alarm
sequence.
[] [0] for Quick Exit on a partially armed system is not
supported.
Quick Exit must not be used when auxiliary delay zones
are force armed. Turn light 6 in section [17] off to ensure
proper operation.
Note: Quick exit shall not be enabled on UL listed
systems.
Keypad Zones
There are three zones which can be activated from the
keypad. The alarm and restoral codes for keypad zones
are programmed using the [][8] command.
Pressing the [F] key or the [1] and [3] keys for 2 seconds
activates a Fire alarm. The fire alarm sounds the siren/bell
in a pulsed mode and is annunciated as a memory
condition. The Fire key can be turned off in section [18].
Pressing the [A] key or the [4] and [6] keys for 2 seconds
activates an Auxiliary keypad zone. If a reporting attempt
is made to an alarm receiver and it is successful the
PC2550 will acknowledge the transmission with a short
series of beeps from the keypad.
Pressing the [P] key or the [] and [#] keys for 2 seconds
activates the Police (or Panic) alarm. The panic alarm can
be programmed for audible or silent operation (see
sections [15] and [18] in “Programming Guide”).
There is no light annunciation from the keypad for the last
two keypad zones, however, the keypad buzzer beeps 3
times to confirm activation on any of the keypad zones.
See section [11] for alarm and restoral codes for all three
keypad zones.