P R O G R A M D E S C R I P T I O N S
34
If no code is entered the panel will Auto-Arm. If a zone is violated the panel will transmit a Partial Closing
Reporting Code
if programmed to indicate the system was not secure. If the zone is restored the panel
will add the zone back into the system.
If the No Activity Arm
option for a partition is programmed with a number other than 000, the partition will
Auto-Arm if no activity is detected for the programmed number of minutes.
The timer will begin when a delay type zone assigned to the partition is secured. The timer is
stopped if any zone assigned to the partition is tripped. The timer will restart when a delay type
zone is again restored.
When the timer expires the panel will sound the buzzer of all keypads assigned to the Partition for one
minute. If any key is pressed, the Auto-Arm will be aborted.
Zones assigned to both Partitions (Global Zones) will not stop the timer.
Time Date ...................................................... 3.4 [ ] Commands, [ ][6][1] Time and Date
Auto-Arm Time ............................................... 3.4 [
] Commands, [ ][6][3] Auto-Arm Time
Auto-Arm Cancel Reporting Code................. Section [348]
Partial Closing Reporting Code ..................... Section [343]
No Activity Arm (Partition 1) .......................... Section [162]
No Activity Arm (Partition 2) .......................... Section [163]
5.22 Keypad Lockout
The panel can be programmed to ‘lockout’ keypads if a number of incorrect user code entries are made.
After the Number of Invalid Codes Before Lockout has been reached the panel will lock out the keypad
for the Lockout Duration
and log the event to the event buffer. For the duration of the lockout the panel
will sound an error tone when any key is pressed.
Keypad Lockout will reset every hour.
To disable Keypad Lockout program the Number of Invalid Codes Before Lockout
as [000].
Number of Invalid Codes Before Lockout...... Section [012]
Lockout Duration ............................................ Section [012]
Keypad Lockout Reporting Code................... Section [338]
5.23 Keypad Blanking
If the Keypad Blanking Option
is enabled the panel will turn off all lights on the keypads except the
backlighting of the keys if no key is pressed for 30 seconds.
The panel will turn the lights back on if entry delay begins or an audible alarm occurs. The lights will also
come on if a key is pressed or, if the Code Required to Restore Blanking Option
is enabled, a valid User
Code is entered.
If the Power Save Option
is enabled the panel will blank all keypad lights including backlighting when AC
power fails, in order to conserve the back up battery.
Keypad Blanking Option ................................ Section [016], Option [3]
Code Required to Restore Blanking.............. Section [016], Option [4]
Power Save Option ........................................ Section [016], Option [6]
5.24 Loop Response
The normal loop response time for all zones is 500 milliseconds. The panel will not consider a zone
violated unless it is violated for at least 500 milliseconds.
If Zone 8 is Fast Loop Response is enabled the loop response for zone 8 will be 40 milliseconds.
Typically this can be used for vibration type sensors.
Zone 8 is Fast Loop Response ..................... Section [013], Option [5]
5.25 Keypad Tampers
If the Keypad Tampers Enable option is selected the panel will display and transmit a General System
Tamper reporting code if any keypad is removed from the wall. When the keypad tamper is restored the
panel will transmit the General System Tamper Restoral reporting code. All keypads should be properly
installed and secured before enabling this option.