S Y S T E M I N T R O D U C T I O N
2
False Alarm Prevention Features
• Audible Exit Delay • Audible Exit Fault • Urgency on Entry Delay
• Quick Exit • Swinger Shutdown • Recent Closing Transmission
• Communication Delay
Additional Features
• Auto Arm by Partition at Specified Time
• Keypad Activated Alarm Output and Communicator Test
• Keypad Lockout
• Audio Capability using the PC5928 Audio Interface Module which allows local intercom and Central
Station 2-Way Listen in.
• All modules connect to the system via a four wire Keybus up to 1000’/330m from main panel
• Event Buffer can be printed using PC5400 RS232 Serial Interface module
• Supports the ESCORT 5580 Voice Prompt Module with Automation/Lighting Control
• 256 Event Buffer, Time and Date Stamped
• Upload/Download Capability
1.2 Additional Devices
1.2.1 Keypads
A maximum of eight (8) keypads can be connected to the control panel and can be any combination of the
following listed. Different keypads (with function keys) can be used for different size systems; 8 zone, 16
zone and 32 zone.
PC5508 PC5516 PC5532 LCD5500
8 zone LED keypad 16 zone LED keypad 32 zone LED keypad LCD keypad
1.2.2 PC5108 Eight Zone Expander Module
Eight zone expander module can be used to increase the number of zones on
the system. Up to 3 modules can be connected to increase the system zones to
a maximum of 32.
1.2.3 PC5204 Power Supply Output Module
The PC5204 can provide up to 1 Amp of additional power for modules or
devices connected to the control panel. The module requires a 16.5 volt AC 40
VA transformer and 4 AH battery. In addition, the module provides 4
programmable high current voltage outputs. Each output is individually
programmable with 14 different output options available
(See Section 5.10
“PGM Outputs”).
1.2.4 PC5208 Eight Low Current Output Module
Adds eight low current outputs (50 mA) to the control. Each output is
individually programmable with 14 different output options available
(See
Section 5.10 “PGM Outputs”).
1.2.5 Escort5580 Module
This Escort5580 module will turn any touch tone phone into a fully functional
keypad. The module also includes a built-in interface to control up to 32 line
carrier type devices for lighting and temperature control
(See Section 5.26
“Escort5580 Module”).
1.2.6 PC5928 Audio Interface Module
The PC5928 Audio Interface module is a simple way to incorporate paging,
intercom, baby listen-in and door answer to the PC5016 control panel. The
module also has built-in two-way voice capability for central station
(See Section
5.28 “Audio Interface Module”).