1
System Introduction
S E C T I O N 1
1.1 Specifications
Control Panel Specifications
Flexible Zone Configuration:
8 fully programmable zones
37 access codes: 32 user, 1 System Master, 2 Partition Master and 2 Duress
Expandable to 32 zones
Hardwired expansion available using the PC5108 Eight Zone Expansion Module
Normally closed, single EOL or double EOL zone supervision
22 zone types, 7 programmable zone options
2 partitions
Audible Alarm Output:
Supervised bell output (current limited at 3 amps), 12 V
DC
Steady or pulsed output
EEPROM Memory: will not lose programming or system status on complete AC and battery failure
Programmable Outputs:
Up to 14 programmable voltage outputs, 14 programmable options
One high current (300 mA) PGM output on main panel
One low current (50 mA) PGM output on main panel
Eight additional low current (50 mA) PGM outputs available using the PC5208 module
Four high current (1 Amp) PGM outputs available using the PC5204 module
One PC5204 output fully supervised for siren output
Powerful 1 Amp Regulated Power Supply:
550 mA auxiliary supply, 12 V
DC
Positive Temperature Coefficient (PTC) components replace fuses
Supervision for loss of AC power, low battery
Internal clock locked to AC power frequency
Power Requirements:
Transformer = 16.5 VAC, 40VA
Battery = 12 volt 4 Ah minimum rechargeable sealed lead acid
Remote Keypad Specifications:
4 different keypads available:
- PC5508 8 Zone LED Keypad - PC5516 16 Zone LED Keypad
- PC5532 32 Zone LED Keypad - LCD5500 Alphanumeric Keypad
Each keypad has 5 fully programmable function keys
Connect up to 8 keypads
Four wire (Quad) connection to Keybus
Built in piezoelectric buzzer
Digital Communicator Specifications:
Supports all major formats including SIA, Contact ID and 200 baud FSK
Event initiated personal paging
3 programmable phone numbers
2 account numbers
DTMF and pulse dialling
DPDT line seizure
Anti-jam feature
Split reporting of selected transmissions to each telephone number
System Supervision Features
The PC5016 continuously monitors a number of possible trouble conditions including:
AC Power Failure Trouble by Zone Fire Trouble
Telephone Line Trouble Low Battery Condition Bell Output Trouble
Loss of Internal Clock AUX Power Supply Fault Tamper by Zone
Failure to Communicate Module Fault (Supervisory or Tamper)
Zobrazit stránku 0
1 2 3 4 5 6 ... 43 44

Shrnutí obsahu

Strany 1 - System Introduction

1System IntroductionS E C T I O N 11.1 SpecificationsControl Panel SpecificationsFlexible Zone Configuration:• 8 fully programmable zones• 37 access

Strany 2 - 1.2 Additional Devices

G E T T I N G S T A R T E D102.9.4 Fire Zone Wiring - 4 wire Smoke DetectorsAll zones defined as Fire (See Section 5.1 “Zone Definitions”) must be wi

Strany 3 - 1.3 Out of the Box

Keypad CommandsS E C T I O N 311All keypads provide complete information and control of the alarm panel. The panel can be completely programmedvia an

Strany 4 - Getting Started

K E Y P A D C O M M A N D S12To disarm the panel enter the premises through the designated entry/exit door. The keypad will emit asteady beep to warn

Strany 5

K E Y P A D C O M M A N D S13[ ]+[2] Trouble DisplayThe panel constantly monitors itself for several different trouble conditions. If a trouble condi

Strany 6

K E Y P A D C O M M A N D S14[ ]+[3] Alarm MemoryThe ‘Memory’ light will be on if any alarm occurred during the last armed period or if an alarm occu

Strany 7 - 2.6 Keypad Assignment

K E Y P A D C O M M A N D S15How to program Access Code Attributes:“Master Code” attributes cannot change. By default, each code has the attributes o

Strany 8 - 2.8 Removing Modules

K E Y P A D C O M M A N D S16• [7] - Enable Background MusicIf the intercom is being used to provide background music, press the [7] key to toggle th

Strany 9 - 2.9 Zone Wiring

K E Y P A D C O M M A N D S173.5 Function KeysThere are 5 function keys on the PC5016 keypads labelled Stay, Away, Chime, Reset and Exit. The operati

Strany 10 - G E T T I N G S T A R T E D

K E Y P A D C O M M A N D S18[08] - [ ]+[1] Bypass ModeThis function key provides the user with a simple method for entering the Bypass Mode. If a u

Strany 11 - Keypad Commands

How to ProgramS E C T I O N 419The following section of the manual describes how to enter Installer Programming and how to program the varioussection

Strany 12 - 3.4 [ ] Commands

S Y S T E M I N T R O D U C T I O N2False Alarm Prevention Features• Audible Exit Delay • Audible Exit Fault • Urgency on Entry Delay• Quick Exit • S

Strany 13 - K E Y P A D C O M M A N D S

H O W T O P R O G R A M20If you enter information into a section and make a mistake, press the [#] key to exit the section. Select thatsection again

Strany 14

Program Descriptions21S E C T I O N 5The following section explains all the programmable features including how the feature operates, options thatper

Strany 15

P R O G R A M D E S C R I P T I O N S22[08] Standard 24 Hour Fire ZoneWhen violated the panel will immediately latch the alarm output and communicate

Strany 16

P R O G R A M D E S C R I P T I O N S23Zones 1 to 32 Attributes ... Section [101] - [132]Audible/Silent Alarm ...

Strany 17 - 3.5 Function Keys

P R O G R A M D E S C R I P T I O N S245.5 Communicator - Account NumbersThere are two Partition Identifier Codes (or Account Numbers) programmable,

Strany 18

P R O G R A M D E S C R I P T I O N S255.6.3 SIA (Level 2)SIA is a specialized format that will communicate information quickly using frequency shift

Strany 19 - How to Program

P R O G R A M D E S C R I P T I O N S265.7 Communicator - Reporting CodesThe panel can be programmed to report events to a central station. The panel

Strany 20 - 4.5 Viewing Programming

P R O G R A M D E S C R I P T I O N S275.7.6 Priority/EmergencyThe panel will transmit a Keypad Fire Alarm Reporting Code AND the Keypad Fire Restora

Strany 21 - Program Descriptions

P R O G R A M D E S C R I P T I O N S285.8 DownloadingDownloading allows programming of the entire control panel via a computer, modem and telephone

Strany 22 - 5.2 Zone Attributes

P R O G R A M D E S C R I P T I O N S295.10 PGM OutputsThere are 3 different types of Programmable Outputs available. They are listed as follows:• PG

Strany 23 - 5.3 Communicator - Dialing

S Y S T E M I N T R O D U C T I O N3Three addtional devices are available: PC5921 Intercom Audio StationThe PC5921 Intercom Audio Station can be used

Strany 24

P R O G R A M D E S C R I P T I O N S30[10] Latched System EventThe PGM output will activate when any of the selected events occur. It will deactivat

Strany 25

P R O G R A M D E S C R I P T I O N S31When the trouble condition is restored the panel can send a TLM Restoral Reporting Code. Any eventsthat occurr

Strany 26

P R O G R A M D E S C R I P T I O N S325.15 Entry/Exit Delay OptionsUpon arming, the panel will begin the exit delay. If Audible Exit Delay is enable

Strany 27

P R O G R A M D E S C R I P T I O N S335.17 Swinger ShutdownThe swinger shutdown feature is designed to prevent a runaway communicator from tying up

Strany 28 - 5.8 Downloading

P R O G R A M D E S C R I P T I O N S34If no code is entered the panel will Auto-Arm. If a zone is violated the panel will transmit a Partial Closing

Strany 29 - 5.10 PGM Outputs

P R O G R A M D E S C R I P T I O N S35Keypad Tamper Enable ... Section [016], Option [8]General System Tam

Strany 30

P R O G R A M D E S C R I P T I O N S365.29.2 Factory Default Main Panel (Software) and other ModulesStep 1 - Enter the Installer Programming mode.St

Strany 31 - 5.13 Test Transmission

P R O G R A M D E S C R I P T I O N S373. AC/DC Inhibit Arming Enabled: When this option is enabled and there is an AC or DC trouble present on thesy

Strany 32 - 5.16 Event Buffer

Contact IDThe Partition ID Codes must be 4 digits. All reporting codes must be 2 digits.The following is a list of Contact ID reporting codes. The fir

Strany 33 - 5.21 Automatic Arming

39SIA FormatLevel 2 (Hardcoded)The SIA communication format used in this product follows the level 2 specifications of the SIA Digital Communica-tion

Strany 34 - 5.25 Keypad Tampers

Getting StartedS E C T I O N 24The following sections provide a complete description of how to wire and configure devices and zones.2.1 Installation

Strany 35 - 5.29 Default (Factory)

Hookup DiagramP C 5 0 1 6 C O N T R O L P A N E L40

Strany 36 - 5.31 Walk Test (Installer)

LIMITED WARRANTYDigital Security Controls Ltd. warrants the original purchaser that for a period of twelvemonths from the date of purchase, the produc

Strany 37 - Transmission”)

© 1997 Digital Security Controls Ltd.1645 Flint Road, Downsview, Ontario, Canada M3J 2J6Tel. (416) 665-8460 • Fax (416) 665-7498Printed in Canada

Strany 38 - Contact ID

InstallationManualWARNING This manual contains information on limitations regardingproduct use and function and information on the limitations as to

Strany 39 - SIA Format

Table of ContentsSection 1 – System Introduction1.1 Specifications ... 11.2 Additio

Strany 40 - Hookup Diagram

G E T T I N G S T A R T E D5Note: In order to comply with safety requirement IEC950, ensure that when the mains cabling entersthe alarm panel, it is

Strany 41 - WARNING Please Read Carefully

G E T T I N G S T A R T E D6Ensure the plugs and jacks meet the dimension, tolerance and metallic plating requirementsof 47 C.F.R. Part 68, SubPart F

Strany 42

G E T T I N G S T A R T E D7Other DevicesRead the manufacturer’s literature carefully to determine the maximum current requirement (duringactivation

Strany 43 - Installation

G E T T I N G S T A R T E D82.6.1 How to Assign KeypadsAll keypad assignment must be done individually on each keypad on the system.To assign a keypa

Strany 44

G E T T I N G S T A R T E D92.9 Zone WiringThere are several different ways in which zones may be wired, depending on the programming optionsselected