automatically extended to include the day (two digits
01.....31), the month (two digits 01.....12) and the year
(two digits...e.g. 91, 92, 93....etc.).
Installer’s Test
[]+[6]+[MASTER CODE]+[0]
This feature is designed to assist the installer in testing
the system. In this mode, the bell or siren will operate for
two seconds each time a device is tripped and the first
level of memory will be affected. The feature is
automatically disabled when the panel is armed and
disarmed. Each time a zone is tripped or restored in this
mode, a signal, if programmed, will be transmitted to the
monitoring station. If this is not desired, it is possible to
disable the communicator during the test (see section
[15] “1st System Option Code”). A printer, if attached,
will not function if the communicator is disabled.
Notes: Do not use the PC16OUT module during the
installer’s test.
Do not use the installer’s test when the panel is
partially armed.
Setting the Clock
[]+[6]+[MASTER CODE]+[1]
Setting the “System 24 Hour Clock” (item [1]) tells the
system the correct time of day. If the system is without
battery and AC power it cannot continue to keep time.
Therefore when the panel is first powered up or when it
has been without AC power long enough to completely
discharge the stand-by battery, the “System 24 Hour
Clock” must be reset. If the time needs to be reset a
“Trouble #8” will be indicated on the keypad (see [][2]
“System Trouble Command”). If a printer is attached to
the panel, setting the clock must include the day, month
and year. e.g. HH: MM: DAY: MONTH: YEAR.
Auto-arm Time of Day
[]+[6]+[MASTER CODE]+[2]
Note: Auto-arm cannot be used for UL installations.
The PC2550 can be programmed to arm at the same time
each day. Programming item [2] sets this time and the
feature must be enabled as shown in item [5] (see “Auto-
arm Enable” on this page).
At the selected auto-arm time the keypad beeper begins
to sound and the Bell/Siren will pulse once every 10
seconds to alert anyone on the premises that the system
is about to arm. The Bell/Siren pulse can be silenced in
section [17] by turning light 1 on.
The keypad beeper will sound for one minute before auto-
arming unless one of the following two methods is used to
abort the auto-arm.
Auto-arm abort: Any key can be pressed to abort the
auto-arm sequence and silence the keypad during the
one minute pre-alert (this is the default condition).
Auto-arm abort with code: If section [17] light 4 is on,
then a valid 4 digit access code is required to abort the
auto-arm sequence.
The auto-arm will be attempted at the same time the
following day. Any time an auto-arm is aborted using one
of the above methods, the reporting code programmed in
section [08] will be transmitted to the central station.
When the panel does arm by auto-arming, any open
zones will be “Force-armed”. If light 5 in section [18] is
on, the panel will send a partial closing code to let the
central station know zones were bypassed. If section [16]
light 1 is on, the zones that were force-armed will be
identified by transmitting their alarm code along with the
partial closing code.
Quick Arm
[]+[6]+[MASTER CODE]+[4]
The “Quick Arm” feature is enabled by pressing the [4]
key while in the “User Functions Command” section.
When enabled (enabled 3 beeps....disabled one long
beep) the panel can be armed by entering [][0]. The
closing code transmitted for “Quick Arm” is the same as
the code which is programmed for the Master Code.
Auto-arm Enable
[]+[6]+[MASTER CODE]+[5]
Entering [] [6] [Master Code] [5] will enable/disable the
auto-arming feature. When the feature is being enabled,
the keypad buzzer will sound 3 beeps and when being
disabled the buzzer will sound one long beep.
Note: Auto Arm must be disabled on UL Listed
systems.
Door Chime
[]+[6]+[MASTER CODE]+[6]
The “Door Chime” feature is enabled by pressing the [6]
key while in the “User’s Functions Command” section.
When enabled the keypad buzzer will beep quickly 5
times each time any zone defined as a delay or instant
circuit opens or closes. The “Door Chime” feature does
not operate on other zone definitions. Zone bypass may
be used to eliminate “beeping” on doors where it is not
wanted. This feature operates only while the panel is
disarmed.
System Test
[]+[6]+[MASTER CODE]+[8]
The system test feature sounds the bell or siren, lights the
keypad indicators and beeps the keypad buzzer for 2
seconds. If a code is programmed in section [50] it will
be transmitted at the same time.
User Callup
[]+[6]+[MASTER CODE]+[9]
This function is enabled in section [47]. When activated,
the panel will call the downloading computer. The
downloading computer must be waiting for the panel to
call before downloading can be performed.
Utility Output Command
[]+[7] OR []+[7]+[ACCESS CODE]
The programmable output (PGM terminal) on the PC2550
can be made to activate by a command from the keypad.