Communicating via PC-Link
Do not use the PC-Link option unless you will be communicating with accounts that are
v3.0 or later. Disable this option whenever you communicate with PC4020KT v1.0
accounts, or PC4010/4020 accounts that are v2.1 or earlier.
The PC-Link function is a communications mode that uses a direct connection between
your computer and panel. A serial cable is used to link the computer with control panels
that are capable of supporting the PC-Link option. To connect to the panel normally, the
call will be placed using the modem and telephone line, employing the regular protocol
methods. When using the PC-Link method, do the following:
To Initiate a PC-Link Connection:
1. From the Options menu, select “Modem Configuration”. The Modem Configuration
window will be displayed.
2. Select “Enable PC-Link”. An “X” indicates that “Enable PC-Link” is selected. When
PC-Link is selected, all fields on the Modem Configuration window will be grey,
except the Com Port field. A Com port will still need to selected when using PC-
Link. Click the “Save” button. The bottom of the Communications window will now
display the message, “PC-Link Active”.
3. Open the PC4010/4020 v3.0 account to communicate with.
4. Connect the PC-Link Connector to the header
on the PC4010/4020 main board (this 4 pin
connector can be found on the left hand side of
the PC4010/4020).
5. Select the communications function to be
performed (Upload/Download Status function
etc.), from the Communications window. The
message, “PC-Link Active - Waiting for Panel”
will be displayed at the bottom of the
Communications window.
6. Once an option has been selected, the user must then initiate the PC-Link
connection by entering Installers Mode and selecting the Enable PC-Link option.
The keypad being used for installers mode programming will display this message.
“PC-LINK Active (#) To Exit”.
7. Once communication is in progress, the PC4010/4020 will automatically exit
Installer’s mode and the message at the bottom of the Communications window
will change to indicate that the requested communications function is in progress.
8. When the desired DLS function(s) are complete press the “Hang Up” button on the
DLS-2 Communications window. This will disconnect the PC4010/4020 from the
DLS-2 software.
9. Disconnect the PC-Link connector from the PC4010/4020.
NOTE: Do not have the PC-Link cable attached to the panel when communicating
with the modem.
10. Disable the Enable PC-Link option on the Modem Configuration window if no
further PC-Link communications are to be done.
NOTE: The communication rate used during a PC-Link communication is 9600 baud.