Test Button &
LED
Smoke detectors shall be photoelectric 2-wire, 4-wire, or wireless as required to
suit the type of alarm panel being installed and the prevailing UL or ULC require-
ments for the type of building and application.
Smoke detectors shall have a 90 degree detection pattern and shall provide reli-
able detection for all smoke flow directions and velocities. They shall be resistant
to false alarms due to RFI and dust.
All detectors shall allow field sensitivity testing with a magnet or integral push-
button and all shall have built-in automatic self-testing for sensitivity with audible
indication of test failure.
Detectors located in areas where alarm panel siren may not be heard, shall have
a built-in sounder which activates when an alarm occurs.
Detectors located in areas where temperatures may rise to 135°F (57°C) before
sufficient smoke is generated to generate an alarm, shall have an integral heat
sensor to activate an alarm.
Wired detectors shall operate in a voltage range of 10-30VDC or 10-26.4VFWR.
Wireless detectors shall be capable of operating as stand-alone and in wireless
communication with a remote alarm panel. They shall operate on 9V, AA size
alkaline batteries. When in alarm or low battery condition, they shall chirp a
built-in 85dB alarm sounder. If they are installed as part of a system with a remote
wireless alarm panel, they shall also transmit alarm, low battery, and regular
supervisory(at least every 12 minutes) signals to the alarm panel.
* Specifications are subject to change without notice
FEATURES:
Advanced 90° photoelectric detection pattern and
patented smoke chamber for superior detection
and dust resistance
Unique high signal-to-noise ratio and superior RFI
immunity to prevent false alarms
Excellent smoke access provides reliable detection
for all smoke flow directions and velocities
User verification of sensitivity
Solid-state LED indicator light
Locking/non-locking mounting plate
Attractive styling for any decor
UL and ULC listed
Photoelectric Smoke
Detectors & Alarms
Meridian
Revolutionary design incorpo-
rating an advanced 90° photo-
electric detection pattern, a
uniquely designed smoke cham-
ber, and high RFI immunity make
Meridian smoke detectors and
alarms the first choice for superior
detection reliability, and preven-
tion of false alarms.
TM
Digital Security Controls 1645 Flint Road, Downsview, Ontario M3J 2J6
An ISO 9001 Registered Company
ARCHITECTS SPECIFICATIONS
Zobrazit stránku 0
1 2 3 4

Shrnutí obsahu

Strany 1 - Meridian

Printed in Canada 06/96 North American #29001858Printed in Canada 06/96 International #290018595.13in(131mm)2.0in(51mm)Test Button &LED

Strany 2 - 220 SER ES V CURVE

Printed in Canada 06/96 North American #29001858Printed in Canada 06/96 International #29001859MN-220 SERIES - 2 WIRE SMOKE DETECTORS• RED

Strany 3

Printed in Canada 06/96 North American #29001858Printed in Canada 06/96 International #29001859MN-220 SERIES - 2 WIRE SMOKE DETECTORS• RED

Strany 4

Printed in Canada 06/96 North American #29001858Printed in Canada 06/96 International #290018595.13in(131mm)2.0in(51mm)Test Button &LED

Komentáře k této Příručce

Žádné komentáře