Section 4 – Programming Descriptions
15
Section [020] Keypad Zone Assignment
Enter the two-digit zone number to be assigned to each keypad assigned to a specific slot. Only one keypad can be assigned to a specific
slot. See Keypad Assignment. Valid entries are from [00] to [64].
Section [021] Eighth System Option Code
For Future Use
Section [022] Ninth System Option Code
Section [023] Tenth System Option Code
Section [030] Fast Loop Response
This section is used to determine the Loop Response Time for the main panel zones.
Section [101] to [164] Zone Attributes
These sections are used to customize the operation of the zones. There are 9 toggle options in each Section:
Option Description
[1-5] For Future Use
[6] Refer to the PC1616/PC1832/PC1864 Reference Manual for RF Delinquency details.
[7] Future Use
[8] ON: When the system is armed in Stay mode, during the Exit delay, the system will sound 1 beep every 3 second.
OFF: When the system is armed in Stay mode, the system will be silent during the Exit delay.
Option Description
[1] ON: the keypad [F] emergency key will only beep three times to acknowledge the button has been pressed. The system will not
activate the bell output. OFF: the system will activate the bell output and beep the keypad.
[2] Refer to the PC1616/PC1832/PC1864 Reference Manual for 200 Baud Open/Close Identifier details.
[3] ON: the system will only transmit the Test Transmission reporting code if the system is armed at the time the system is programmed
to report the event. OFF: the system will always report the Test Transmission reporting code at the programmed time.
[4] ON: the system changes the Test Transmission Reporting Cycle Time from Days to Hours. OFF: the Test Transmission Reporting
Cycle Time is in Days.
[5] ON: the user can switch from Away Arm mode to Stay Arm mode using the function keys. OFF: the user cannot switch arming
modes.
[6] ON: the system disconnects a listen in/two-way session if a new event occurs.
OFF: the system does NOT disconnect. New events are transmitted only after the session is terminated.
[7] ON: the system does NOT activate the keypad buzzer for any trouble condition. OFF: the system annunciates troubles via the
keypad buzzer (two beeps every 10 seconds) normally.
[8] For Future Use
ON: the loop response time will be 36 mS. OFF: the loop response time will be 400 mS.
Option Description
[1] ON: alarms are audible (bell output). OFF: alarms are silent.
[2] ON: the bell output is steady (burglary). OFF: the alarm output pulses (fire).
[3] ON: a zone violation or restoral will activate Chime. OFF: Chime is not activated.