Installation
Manual
IMPORTANT
This manual contains information on limitations regarding product use and function and information on the
limitations as to liability of the manufacturer. The entire manual should be carefully read.
PC5O2O Version 3.1
DLS-3 v1.3 and higher
WWW.DIYALARMFORUM.COM
Zobrazit stránku 0
1 2 3 4 5 6 ... 52 53

Shrnutí obsahu

Strany 1 - Power 864

Power 864SECURITY SYSTEM®TMInstallation ManualIMPORTANTThis manual contains information on limitations regarding product use and function and informat

Strany 2

5Telephone Connection Terminals - TIP, RING, T-1, R-1If a telephone line is required for central station communication or downloading, connect an RJ-3

Strany 3

6System Outputs (all 12 VDC)Other DevicesRead the manufacturer’s literature carefully to determine the maxi-mum current requirement (during activation

Strany 4 - Table of Contents

Installation and Wiring: 2.9 Removing Modules7In LED keypads, zone lights will be turned on according to what modules the panel has found on the syste

Strany 5 - PC5020 Wiring Diagram

8Fire Zone Wiring - 4-wire Smoke DetectorsAll zones defined as Fire (see section 5.3 Basic Programming PWS Sect 3 on page 17) must be wired according

Strany 6 - Section 1: Introduction

9Section 3: How to ProgramThe following section of the manual describes how to enter Installer Programming and how to program the various sections.NOT

Strany 7

10Section 4: Keypad CommandsUse any system keypad to enter commands, or to program the Power864 security system. The LED keypad uses function and zone

Strany 8

11A bypassed zone will not cause an alarm. Instructions on zone bypassing can be found in the Power864 Instruction Manual (“Zone Bypassing”). When the

Strany 9

12[✱] [3] Alarm MemoryThe ‘Memory’ light will be on if any alarm occurred during the last armed period or if an alarm occurred while the panel was dis

Strany 10 - WWW.DIYALARMFORUM.COM

Keypad Commands: 4.3 Function Keys13Scroll to the day of the week you want to change, or enter the number of the day (1-7 for Sunday to Saturday). On

Strany 11

14select Partition 1 (see section 4.4 Global and Partition Keypad Opera-tion on page 15).[02] - Select Partition 2Provides an easy way to select Parti

Strany 12

New FeaturesPC5200 SupportThe PC5020 v3.1 supports the new PC5200 Power Supply module. See PC5200 Power Supply Output Module, Pg 2.PC5936 Support The

Strany 13

Keypad Commands: 4.4 Global and Partition Keypad Operation154.4 Global and Partition Keypad OperationA global keypad will display limited information

Strany 14 - Section 3: How to Program

16Section 5: Programming SectionsThe structure of this section corresponds with the structure of the Programming Worksheets (PWS) and is intended to b

Strany 15 - Section 4: Keypad Commands

Programming Sections: 5.1 For the Record PWS Sect 1175.1 For the Record PWS Sect 1This Section identifies the Client, Installation Date, Installers Co

Strany 16

18[005] - System TimesThis section has 9 sub-sections, 1 for each of the 8 partitions, and 1 for the Bell timeout. A 2-digit entry is required to acce

Strany 17

19[006] - Installer’s Code. Installer Lockout Enable . . . . . . . . . . . . . . . . . . . . . . Section [990]Installer Lockout Disable . . . . . .

Strany 18

2010 Latched System Event (Strobe). This output will activate when any of the selected system events (alarms) occur on the system. In the armed state,

Strany 19

Programming Sections: 5.3 Basic Programming PWS Sect 321[012] - Keypad Lockout OptionsThe panel can be programmed to ‘lockout’ keypads if a series of

Strany 20

22Option Definition On/Off Description2 Bell During Auto-ArmON Bell Squawk During Auto-Arm Enabled. The Bell output will sound a single squawk every 1

Strany 21

Programming Sections: 5.3 Basic Programming PWS Sect 323Option Definition On/Off Description7 Telephone Line Monitor ON Telephone Line Monitor enabled

Strany 22

24Option Definition On/Off Description3 Audible RF Jam Trouble BeepsON Audible RF Jam Trouble BeepsOFF An RF Jam will not sound Trouble Beeps4 Double

Strany 23

PC5020 Installer Programming Quick Reference Chart SIA False Alarm ReductionMinimum requirement system for SIA-FAR Installations :• 1 PC5020 Control p

Strany 24

Programming Sections: 5.3 Basic Programming PWS Sect 325Option Definition On/Off Description2 Verbal Door Chime ON Verbal Door Chime is Enabled. The s

Strany 25

26[020] - Keypad Zone Assignment Assigning Keypad ZonesEach keypad has a zone input to which a device (i.e. a door contact) can be connected. (See Sec

Strany 26

Programming Sections: 5.5 Partition & Zone Programming27occurs after this timer expires, the Police Code will not be logged or transmitted, and th

Strany 27

28Telephone numbers can be up to 32 digits which will allow you to add special digits if required. To program the telephone number enter numbers 0 thr

Strany 28

Programming Sections: 5.6 Communicator Programming PWS Sect629Alarm Canceled: this reporting code will be sent if a valid access code is entered durin

Strany 29

30General System Trouble Restoral: a General System Trouble Restoral Reporting Code will be transmitted when the panel detects none of the following:

Strany 30

Programming Sections: 5.6 Communicator Programming PWS Sect631SIA Sends Automatic Reporting Codes . . .Section [381], Option [3]Communicator Call Dire

Strany 31

32This section requires 2 two digit entries (1 per phone number). The 3rd telephone number uses the format programmed for the 1st tele-phone number.Re

Strany 32

Programming Sections: 5.6 Communicator Programming PWS Sect633[378] - Test Transmission Time of DayProgram the time of the test transmission in this s

Strany 33

347 LINKS Dialing ON Call LINKS as well as Land-line(s). The control panel will dial the programmed number of attempts through the LINKS, followed by

Strany 34

iTable of ContentsSection 1: Introduction 11.1 About the Power864 System ... 11.2 About the Power864 Manual Set

Strany 35

35 [390]-[393] LINKS PreamblesDownloading can be performed through the LINKS1000 cellular communicator if the telephone line is disconnected. If usin

Strany 36

36Redundant CommunicatorThe panel can be programmed to call using the land line and the LINKS1000 cellular communicator when an event occurs. To progr

Strany 37

37[402] - Downloading Computer’s Telephone NumberThis telephone number is 32 digits in length. [403] - Downloading Access CodeThis 4-digit Hexadecimal

Strany 38

38[551]-[564] PGM Partition AssignmentThe PC5020 has a 8-bit toggle field per output that determines which partitions the output is assigned to (outp

Strany 39

Programming Sections: 5.10 Module Programming PWS Sect 1039[703] - Delay Between Dialing AttemptsFor standard (force) dialing, the panel will go off-h

Strany 40

40Periodic Camera TestWhen the Periodic Camera Test option is enabled, the panel will test cameras connected to a PC5108L module every 30 minutes. Onl

Strany 41

Programming Sections: 5.11 Special Installer Instructions PWS Sect 1141[991][Installer Code] - Installer Lockout DisableThis disables the Installer Lo

Strany 42

42Appendix A: Reporting CodesThe following tables contain Contact ID and Automatic SIA format reporting codes. For more information on reporting code

Strany 43

Reporting Codes43Section # Reporting Code Code Sent When...Dialer Direction*Automatic Contact ID CodesSIA Auto Rep Codes**[344] Special Opening Openin

Strany 44

44Table2: Contact ID Zone Alarm/Restoral Event Codes (as per ADEMCO):Program any of these codes for zone alarms/restorals when using the standard (non

Strany 45

iiPC5020 Wiring DiagramNOTE: AUX+ (420mA) isshared between AUX+,Keybus and all PGM outputsWARNING: Not to be removed by anyone except occupant. This e

Strany 46

FCC COMPLIANCE STATEMENTCAUTION: Changes or modifications not expressly approved by DigitalSecurity Controls Ltd. could void your authority to use thi

Strany 47 - Appendix A: Reporting Codes

WARNING Please Read CarefullyNote to InstallersThis warning contains vital information. As the only individual in contact with system users, it is you

Strany 48

NOTESWWW.DIYALARMFORUM.COM

Strany 49

©2001 Digital Security Controls Ltd., Toronto, Canadawww.dsc.com Printed in Canada 29005882 R001 PC5020 Module CompatibilityModule Compatible? Comm

Strany 50

1Section 1: Introduction1.1 About the Power864 SystemThe Power864 is a high end security system. It supports up to 64 zones, 8 separate partitions, an

Strany 51

2False Alarm Prevention Features• Audible Exit Delay• Audible Exit Fault • Urgency on Entry Delay• Quick Exit• Swinger Shutdown• Recent Closing Transm

Strany 52

Introduction: 1.4 Additional Devices3For more information on either module, see their respective installa-tion manuals.NOTE: The PC5108L module can o

Strany 53

4Section 2: Installation and WiringThe following sections provide a complete description of how to wire and configure devices and zones.2.1 Installati