©2003 Digital Security Controls Ltd.
Toronto • Canada • www.dsc.com
Technical Support: 905-760-3036
Printed in Canada
Direct all comments concerning this publication to [email protected]
WARNING: This manual contains information on limitations regarding product use
and function and information on the limitations as to liability of the manufacturer.
Read the entire manual carefully.
NT9005-433AUS V1.0
32 ZONE SECURITY SYSTEM
Compatible with DLS2002 (and higher) downloading software
Installation & Programming Guide
WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM
Zobrazit stránku 0
1 2 3 4 5 6 ... 29 30

Shrnutí obsahu

Strany 1 - WWW.DIYALARMFORUM.COM

©2003 Digital Security Controls Ltd.Toronto • Canada • www.dsc.comTechnical Support: 905-760-3036 Printed in Canada Direct all comments concerning thi

Strany 2

61-5 OperationStay Armed - (Ready light is OFF, Stay icon is ON, Bypass icon is ON), This mode is activated by press-ing a function key programmed for

Strany 3

46Module Programming[804]-[82-85] Zone Transmitter Supervision Options These eight bit toggle sections determine which wireless zones on the system ar

Strany 4

82-2 NT9005 Installation2-2.1 Back Cover Removal:Figure 3.1. Place the unit face down on a surface that will not scratch or mar the front cover.2. Rem

Strany 5

44[702] Second International Option CodesOFF Land line Test Transmission is in Days !The value programmed in section [370] option 7 is in days.4 ON 1

Strany 6

102-3 System WiringPGM 1 and PGM 2 - are programmed in section [009], output attributes are programmed in section [141] and [142]. PGMs 11, 12, 13, 14

Strany 7

42Section [400] DownloadingDownloadingDownloading allows programming of the entire system via a computer, modem and telephone line or PC-Link. All fun

Strany 8

12Chapter 3: Programming3-1 Programming OverviewThere are three methods of programming the NT9005: Flash Programming, Advanced Program-ming, and downl

Strany 9

40Default 003 I___I___I___I 000-014 transmissions[4] Transmission DelayThis value defines the delay before transmission. The delay is for zones which

Strany 10

143-3 [*] Functions[*][1] ZONE BYPASSINGWhen Disarmed - A bypassed zone will not cause an alarm. If a zone is bypassed the panel can be armed (Ready

Strany 11

38This code is sent when the 128 event internal buffer has reached a level of 75% full since the last successful upload from a downloading computer.I_

Strany 12

Limited WarrantyDigital Security Controls Ltd. warrants the original purchaser that for aperiod of twelve months from the date of purchase, the produc

Strany 13

163-3 [*] FunctionsUser access codes are intended to be unique for each user. This allows the system to identify the user (by logging to the event buf

Strany 14

36[338] Misc. Tamper CodesThese codes are sent to the Tamper Alarm and Restorals Call Direc-tion Group programmed in section [363].I_3_I_7_I General

Strany 15

18Chapter 4: Flash ProgrammingFlash ProgrammingFLASHFlash Programming provides a quick way to program the system when standard options are selected

Strany 16

34[301]-[311] Telephone NumbersThe telephone numbers entered here are for use by the system to send reporting codes to the central monitoring station,

Strany 17

20Chapter 5: Advanced Programming5-1 Section Overview[000] Keypad Programming . . . . . . . . . . . . . . . . . . . . . 21[001]-[004] Zone Definition

Strany 18

32SectionZoneDefinitionAudible SilentSteady PulsedChimeBypassForce ArmSwingTx DelayWireless Zn.1 2345678[101] 01 ( )        [102]

Strany 19

2211 [*][5] User Programming - Console Only - Pressing this key is the equivalent of entering [*][5]. A Supervisor or Master access code is required

Strany 20

30[017] Fifth System Option Codes1 ON WLS Key does not use Access Code !The panel will NOT accept the disarm keycode from an uni-dentified wireless k

Strany 21

2420 24-Hr Freeze - Similar to 24-Hr Burglary except for Sys-tem Event output type and SIA identifier.21 24-Hr Latching/Tamper - If this zone is viola

Strany 22

28OFF Audible Exit Fault Disabled For [*][9] arming, if Audible Exit fault is enabled, a vio-lated zone will begin Entry Delay as indicated. If this

Strany 23

54High Traffic Shutdown ModeTo prolong battery life, the motion detector uses the High Traffic Shutdown feature. When motion is detected, the device

Strany 24

2610 System Event (with Event Options) - Latched System Event (Strobe). The PGM output switches to ground when any of the selected System Events (Alar

Strany 25

WARNING Please Read CarefullyNote to InstallersThis warning contains vital information. As the only individual in contact withsystem users, it is your

Strany 26

52Appendix C: WLS925L-433 Mini Door/Window Contact Remove CoverAt the notched location on the cover, insert the flat blade of a small screwdriver betw

Strany 27

21-2 System Specifications1-2 System SpecificationsThe NT9005 system supports up to 32 system users. The system can be programmed using the keypad on

Strany 28

50Table2: Contact ID Zone Alarm/Restoral Event Codes (as per ADEMCO):Program any of these codes for zone alarms/restorals when using the standard (non

Strany 29

41-4 NT9005 Labels & Console1-4 NT9005 Labels & ConsoleThe NT9005 system comes with peel off instructions which list the Flash Programming ste

Strany 30

48Appendix A: Reporting CodesThe following tables contain Contact ID and Auto-matic SIA format reporting codes. For more informa-tion on reporting co