1
TABLE OF CONTENTS
INTRODUCTION 3
Features .................................................................................................................................................. 3
Specifications.......................................................................................................................................... 3
INSTALLATION 4
Mounting the Panel ................................................................................................................................. 4
Mounting the Keypad.............................................................................................................................. 4
Wiring ...................................................................................................................................................... 5
Burglary Zone Wiring .............................................................................................................................. 5
Auxiliary Power Connection .................................................................................................................... 5
PGM Terminal Connections .................................................................................................................... 5
STR Terminal Connection ....................................................................................................................... 5
KEY Terminal Connection ....................................................................................................................... 6
AC Power Wiring ..................................................................................................................................... 6
Battery Connection ................................................................................................................................. 6
Telephone Line Wiring ............................................................................................................................ 6
KEYPAD FUNCTIONS 7
Introduction ............................................................................................................................................. 7
Master Code............................................................................................................................................ 7
Installer’s Programming Code ................................................................................................................ 7
Arming..................................................................................................................................................... 7
Auto-Bypass/Stay-Away Arming ............................................................................................................. 7
At-Home Arming...................................................................................................................................... 7
Disarming ................................................................................................................................................ 8
Important Note about Keypad [
] Commands ...................................................................................... 8
[
]+[0]:Quick-Arm.................................................................................................................................. 8
[
]+[1]+[Access Code]: Zone Bypassing ............................................................................................. 8
[
]+[2]:Display Trouble Conditions ....................................................................................................... 8
[
]+[3]:Display Alarm Memory .............................................................................................................. 9
[
]+[4]:Bell Test ..................................................................................................................................... 9
[
]+[5]+[Master Code]: Program Access Codes ................................................................................. 9
[
]+[6]:Door Chime On/Off .................................................................................................................... 9
[
]+[7]:Utility Output Command ............................................................................................................ 9
[
]+[8]+[Installer’s Code]: Installer’s Programming Command .......................................................... 10
[
]+[9]+[Access Code]: At-Home Arming........................................................................................... 10
Keypad Zones....................................................................................................................................... 10
Adjusting the Keypad Sounder Tone and Backlighting ....................................................................... 10
WWW.DIYALARMFORUM.COM
Zobrazit stránku 0
1 2 3 4 5 6 ... 26 27

Shrnutí obsahu

Strany 1 - WWW.DIYALARMFORUM.COM

1TABLE OF CONTENTSINTRODUCTION 3Features ...

Strany 2

10[∗]+[8]+[Installer’s Code]: Installer’s Programming CommandThe PC560 is programmed from the keypad by using commands in the [∗][8][Installer’s Code

Strany 3

11PROGRAMMING GUIDEWith the panel disarmed, enter [∗][8][Installer’s Code]. The panel can only be programmed while it isdisarmed. The default Instal

Strany 4

12Resetting Programming to the Factory Default SettingsThe system may be reset to its factory default programming by following this procedure:1 Remove

Strany 5

13PROGRAMMING SECTIONS[01] Zone DefinitionsEnter four 2-digit numbers in this section to determine the operating characteristics of each zone.Zone Def

Strany 6

14[02] System TimesThree system times are programmed in Section [02]; each time requires a 3-digit number. Do not press the [#]Key during data entry.

Strany 7

15[05] First System Option CodeWhen Section [05] is entered, the 4 Zone Lights will be ON or OFF to indicate which options are selected.To turn a Zone

Strany 8

16[07] Third System Option CodeRefer to Section [05] for programming information.LIGHT[1] • ON = Restorals reported on Disarming*OFF = Restorals repor

Strany 9

17[13] Maintenance and Priority CodesMaintenance Codes are transmitted to indicate various trouble conditions and their restorals; Priority Codesare u

Strany 10

18FOR THE RECORDCustomer ___________________________________________________________________________________Address __________________________________

Strany 11

19[01] Zone Definitions Page 13NOTE: When defining zones, assign Delay Zones starting with Zone 1, then Zone 2, and so on.Then, assign the other z

Strany 12

2PROGRAMMING GUIDE 11Sections [05] through [07]: Enabling System Functions ... 11HE

Strany 13

20[06] Second System Option Code Page 15Default Zone Light ON Zone Light OFFON Zone Light 1 DTMF dialing Pulse dialingOFF Zone Light 2 1400Hz Hands

Strany 14

21[11] Zone Alarm and Restoral Reporting Codes Page 16For single digit reporting codes, enter [0] as the second digit.Zone 1 Alarm Enter [∗1∗] (HEX

Strany 15

22[13] Maintenance and Priority Codes Page 17[P] Key Alarm[A] Key Alarm[F] Key AlarmBattery TroubleBattery RestorePeriodic Test CodePolice Code[14

Strany 16

23HOOK-UP DIAGRAMWWW.DIYALARMFORUM.COM

Strany 17

LIMITED WARRANTYDigital Security Controls Ltd.’s liability for failure to repair the prod-uct under this warranty after a reasonable number of attempt

Strany 18

WARNING Please Read CarefullyNote to InstallersThis warning contains vital information. As the only individual in contactwith system users, it is your

Strany 19

© 1997 Digital Security Controls Ltd.1645 Flint Road, Downsview, Ontario, Canada M3J 2J6Printed in Canada 29000870 R3WWW.DIYALARMFORUM.COM

Strany 20

InstallationManualPC56O• W A R N I N G •This manual contains information on limitations regarding product use andfunction and information on the limit

Strany 21

3INTRODUCTIONFEATURES• Fully featured security system with TroubleSupervision, Alarm Memory, Master Code and 3programmable Access Codes, Quick-Arming

Strany 22

4INSTALLATIONMounting the PanelSelect a dry location close to an unswitched AC source, a ground connection, and the telephone connection.Remove the pr

Strany 23

5WiringNOTE: Complete all wiring to the control panel before applying battery or AC power.If the neutral in the main supply is not readily identifiab

Strany 24

6KEY Terminal ConnectionThe KEY terminal may be programmed for keyswitch operation or for use as a tamper zone. Refer to theHook-up Diagram in the ba

Strany 25

7KEYPAD FUNCTIONSIntroductionThe Keypad provides complete control of the PC560 control panel. The panel can be completely programmedfrom the keypad.

Strany 26

8DisarmingEnter the premises through the designated Entry-Exit door. The keypad will be sounding a tone to indicate thatthe system must be disarmed.

Strany 27 - Installation

9[∗]+[3]: Display Alarm MemoryAlarms caused during the previous armed period are stored in memory. To display the zones that went intoalarm, enter [