DSC NT9005 V1.0 Specifikace Strana 13

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 30
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 12
44
[702] Second International Option Codes
OFF Land line Test Transmission is in Days !
The value programmed in section [370] option 7 is in days.
4 ON 1600 Hz Handshake
The communicator responds to a 1600Hz handshake for
bps formats.
OFF Standard Handshake !
The communicator responds to the handshake desig-
nated by the format selected in section [360].
5 ON I.D. Tone Enabled
After the telephone number is dialed, the system emits
the tone programmed in option 6.
OFF I.D. Tone Disabled !
6 ON I.D. Tone Frequency = 2100 Hz
This tone is enabled in option 5.
OFF I.D. Tone Frequency = 1300 Hz !
This tone is enabled in option 5.
7 ON 1-Time/1-Hour DLS Window enabled
Allows the user to initiate a DLS downloading session.
OFF 6-Hour DLS Window enabled !
8 ON Bell on FTC when Armed
If a failure to communicate trouble is generated while the
system is armed, the bell output will sound for the time pro-
grammed in section [005] or until the system is disarmed.
OFF FTC Trouble only when Armed. !
If a failure to communicate trouble is generated while the
system is armed, the bell output will not sound but the key-
pad buzzer will sound trouble beeps until a key is pressed.
[703] Delay between Dialing Attempts
For standard (force) dialing the system will search for a dialtone
for 5 seconds, hang up for 20 seconds, search for a dial tone for
5 seconds then dial. If there is no initial handshake recognized
within 40 seconds, the system will hang up. This timer adds a
delay before the next call is attempted. The default is one sec-
ond (001) delay for a total of six seconds.
Default 001 I___I___I___I 000 - 255 second
2-3 System Wiring
9
the wall. Slide tabs on bottom of unit into the
slots of the back cover.
4. Secure unit in place with the two screws pro-
vided.
2-3 System Wiring
The R, B, Y1, G2 terminals located on the inside of
the back cover, can be configured as a Keybus, or 2
hardwired zones or 2 PGMs (programmable out-
puts), or 1 PGM and 1 hardwired zone . If config-
ured as a Keybus or hardwired zone, wire devices
using 22 AWG stranded wire; maximum wire run
distance must not exceed 1000 ft. (305 m.).
2-3.1 Keybus Wiring
The Keybus is used to communicate to other mod-
ules on the system. In this configuration the ‘R’ ter-
minal is +6V
DC
, the B terminal is ground, Y1
terminal is the CLOCK and the G2 terminal is the
DATA. If the system is configured for Keybus then
Keybus Enabled (section [018] option 1) must be
ON. Hardwired zones 1 and 2, and PGMs 1 and 2
will not be available. If an NT9204 module is con-
nected to the system (via the Keybus) then PGMs
11, 12, 13 and 14 will be available. Enter [00] in
section [030] when an NT9204 is used.
The Keybus can not drive any module other
than the NT9204 directly. To connect to Sky-
route®, an NT9204 module must be con-
nected to the Keybus.
2-3.2 Programmable Output Wiring
Programmable outputs (PGMs) are available directly
from the system panel or from the NT9204 module.
When activated, the output will switch to ground.
PGM outputs can be programmed in any of the
options listed in section [009] and can be custom-
ized using up to 8 attributes, see section [141].
PGMs 3 through 10 are not supported at this
time.
PGMs 1, 2 - PGM 1 and 2 can sink 50 mA. This out-
put can drive an LED indicator or small buzzer
directly. Connect Y1 (PGM 1) or G2 (PGM 2) to the
negative (-) terminal of the device and connect the
positive terminal of the device to the R terminal. If
current greater than 50 mA, or voltage greater than
6 V
DC
is required for an application then a relay
must be used.
Example of Keybus Wiring
Module A is wired correctly
(within 1000’/305m of the panel)
Module B is wired correctly
(within 1000’/305m of the panel)
Module C is NOT wired correctly
(greater than 1000’/305m from the
panel)
*
**
* Not used for UL Installations
Use an external source for power that is UL Listed
to UL1481 for Fire and UL603 for Burglary.
** Model
PTD920T-ANZ
GRN YEL BLK RED AC AC
J1
UA440
GRN YEL BLK RED AC AC
J1
UA440
Jumper J10 must
be in place for
tamper to work
Tamper
Switch
Backup
Battery
Figure 5
WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM
Zobrazit stránku 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 29 30

Komentáře k této Příručce

Žádné komentáře