Section 3: Basic Programming
Zone Definitions
NOTE:To use 24-hour Buzzer zones, keypads must be installed .
NOTE:Keypad zones are assigned in section [020]. Zone Attributes are assigned in sections [101] - [132]. Zone assignment is
in sections [202] - [261].
00 Null Zone (Not Used) 12 24 Hour Holdup* 23 Maintained Keyswitch Arm*
01 Delay 1* 13 24 Hour Gas* 24 LINKS1000 Answer*
02 Delay 2* 14 24 Hour Heating* 25 Interior Delay*
03 Instant* 15 24 Hour Auxiliary* 26 24 Hour Non-alarm*
04 Interior* 16 24 Hour Panic* 27 Delayed 24 Hour Waterflow
05 Interior, Stay/Away* 17 24 Hour Emergency* 28 Instant 24 Hour Waterflow
06 Delay, Stay/Away* 18 24 Hour Sprinkler* 29 Auto Verified Fire
07 Delayed 24 Hour Fire (Hardwired)** 19 24 Hour Water* 30 Fire Supervisory
08 Standard 24 Hour Fire (Hardwired) 20 24 Hour Freeze* 31 Day Zone*
09 24 Hour Supervisory 21 24 Hour Latching Tamper* 87 Delay 24 Hour Fire (Wireless)**
10 24 Hour Supervisory Buzzer* 22 Momentary Keyswitch Arm* 88 Standard 24 Hour Fire (Wireless)**
11 24 Hour Burglary*
*For burglary applications only
** For residential fire applications only
Section # Zone # Default
Zone
Defn.
[001]
01 01 I_____I_____I
02 03 I_____I_____I
03 03 I_____I_____I
04 03 I_____I_____I
05 04 I_____I_____I
06 04 I_____I_____I
07 04 I_____I_____I
08 04 I_____I_____I
09 00 I_____I_____I
10 00 I_____I_____I
11 00 I_____I_____I
12 00 I_____I_____I
13 00 I_____I_____I
14 00 I_____I_____I
15 00 I_____I_____I
16 00 I_____I_____I
[002]
17 00 I_____I_____I
18 00 I_____I_____I
19 00 I_____I_____I
20 00 I_____I_____I
21 00 I_____I_____I
22 00 I_____I_____I
23 00 I_____I_____I
24 00 I_____I_____I
25 00 I_____I_____I
26 00 I_____I_____I
27 00 I_____I_____I
28 00 I_____I_____I
29 00 I_____I_____I
30 00 I_____I_____I
31 00 I_____I_____I
32 00 I_____I_____I