TLM and Alarm (14)
The output will activate when a telephone line trouble is
present and an alarm occurs on any of the selected parti-
tions.
Failure To Communicate (15)
The output will activate when a Failure to Communicate
trouble is present. The output will stay activated until a
successful communication is sent to the central station.
Communications Active (16)
The output will activate while the panel is attempting to
communicate with the central station.
Ground Start (17)
The output will activate for a programmable number of
seconds before the panel attempts to communicate with
the central station.
NOTE: This output will follow the “Ground Start” PGM
pulse time (see Section 11.3 “PGM Output Pulse Times”).
This output shall not be used on UL listed systems.
Kissoff Output (18)
The output will activate for a programmed number of
seconds after a successful communication to the central
station.
NOTE: This output will follow the “Kissoff Pulse” PGM
pulse time (see Section 11.3 “PGM Output Pulse Times”).
Combus Power (19)
This output will deactivate when a Combus reset is per-
formed by the panel.
Ready Status (20)
The output will activate when all the selected partitions
are ready to be armed. If any of the selected partitions are
not ready, the output will deactivate.
Zone Alarm (21)
This output will annunciate when a selected zone has
gone into alarm. Any zone can be selected. If the zone
goes into alarm, the output will activate. The output will
remain active until the partition is armed again.
Zone Follow (22)
This output will follow a selected zone. Any zone can be
selected. If the zone is opened, tampered, or faulted, the
output will activate. When the zone is secured, the output
will deactivate. If the Follows + Alarms system toggle
option is enabled, when the zone goes into alarm the output
will remain active until the partition that the zone belongs
to is armed or disarmed (ref #[000200]).
Duress (23)
This output will activate when a Duress code is used to
perform any function.
NOTE: This output will follow the Duress pulse timer
(see Section 11.3 “PGM Output Pulse Times”).
Buzzer Follow (24)
This output will activate when any of the following
occur on the selected partitions: an entry delay, an auto-
arm pre-alert, or a 24HR Buzzer zone alarm.
Remote Operation (25)
This option can be activated remotely using download-
ing, and will remain active until deactivated by the
downloading computer.
Exit Follow (26)
This option will follow the exit delay for the selected par-
tition(s).
Entry Follow (27)
This output will follow the entry delay for the selected
partition(s).
Zone Tamper (28)
This output will activate when any zone tamper alarm
occurs on the selected partitions. It will remain active
until the partition is disarmed (alarm silenced) or the bell
time-out is reached.
Zone Fault (29)
This output will activate when any zone fault alarm
occurs on the selected partitions. It will remain active
until the partition is disarmed (alarm silenced) or the bell
time-out is reached.
Zone Tamper Follow (30)
This output will indicate when a zone goes into a tamper
alarm. Any zone can be selected. If the zone is tampered,
the output will activate; when the zone is restored, the
output will deactivate. When the Follows + Alarms sys-
tem toggle option is enabled, the output will remain
active until the partition that the zone belongs to is
armed (ref #[000200]).
Zone Fault Follow (31)
This output will indicate when a zone goes into a fault
alarm. Any zone can be selected. If the zone is faulted, the
output will activate; when the zone is restored, the output
will deactivate. When the Follows + Alarms system toggle
option is enabled, the output will remain active until the
partition that the zone belongs to is armed (ref #[000200]).
Armed Stay Mode (32)
This output will activate when a selected partition is
armed in the Stay mode (i.e. when the partition is armed
with Stay/Away zones bypassed).
Armed Away Mode (33)
This output will activate when a selected partition is
armed in the Away mode (i.e. when all Stay/Away zones
are active).
2-wire Smoke Alarm (34)
The output will follow the alarm status on the PC4701 2-
wire smoke input, if installed. If the input is in alarm, the
output will activate; when the alarm is restored, the out-
put will deactivate.
2-wire Smoke Trouble (35)
The output will follow the trouble status on the PC4701
2-wire smoke input, if installed. If the input exhibits a
trouble, the output will activate; when the trouble is
restored, the output will deactivate.
Waterflow Alarm (36)
The output will follow the alarm status on the PC4701
Waterflow input, if installed. If the input is in alarm, the
output will activate; when the alarm is restored, the out-
put will deactivate.
Waterflow Trouble (37)
The output will follow the trouble status on the PC4701
Waterflow input, if installed. If the input exhibits a trou-
ble, the output will activate; when the trouble is restored,
the output will deactivate.
Command Outputs 1-8 (38-45)
The output will activate when the corresponding [*] [7]
[1-8] command is entered on the selected partition. Enter
a pulse time for each output (default = 000 seconds; 005
seconds for Command Output #2). A pulse time of [000]
will allow the output to be toggled on and off using the
corresponding [*] [7] [1-8] command.
NOTE: All command outputs will deactivate when you
exit installer’s mode.
HINT: If you program more than one PGM for the same
command output (eg. command output 1), make sure
that either: