26 ••Refer to section xx and page xx in the Installation Guide.
Section 9: Special Installer Functions
[901] Installer Walk Test Mode Enable / Disable (2.3.22 “Walk Test” on page 56••)
[904] Wireless Module Placement Test
You can conduct placement tests using the NT9010 Flash Programming, or using this section. Each device must
pass three consecutive tests in order to be fully enrolled on the system. For more information, please refer to your
NT9010 Installation Manual.
NOTE: Local annunciation must be enabled for Module Placement Feedback [017], option 4. [904]
will not auto change to high volume for module placement.
• Select the module / transmitter (Zones 01-32).
• Press [#] to Cancel.
[990] Installer Lockout Enable
(2.3.21 “Installer Lockout” on page 55••)
[991] Installer Lockout Disable (2.3.21 “Installer Lockout” on page 55••)
[992] Restore Main Controller Programming to Factory Default Settings
(2.3.20 “Factory Default” on page 54••)
[995] Restore Audio Interface Programming to Factory Default Settings
(2.3.20 “Factory Default” on page 54••)
[996] Restore Wireless Receiver Programming to Factory Default Settings
(2.3.20 “Factory Default” on page 54••)
[999] Restore All NT9010 Programming to Factory Default Settings
(2.3.20 “Factory Default” on page 54••)
NOTE: It is recommended that a full default [999] be preformed to restore all defaults.
Placement Bell / Buzzer
Good 1 Beep / Squawk
Bad 3 Beeps / Squawks