Section 2.3: Changing Other NT9010 Functions
49
Zone Restorals
If the Restoral on Bell Time-out option is selected, the system will send the Zone
Restoral Reporting Code for the zone if the bell cut-off time has expired and the
zone is secured. If the zone is not secured when the bell cut-off time expires, the
system will send the restoral immediately once the zone is secured, or when the
system is disarmed. If the Restoral on Bell Time-out option is not selected, the
system will immediately send the Zone Restoral Reporting Code when the zone is
secured, regardless of whether or not the alarm output is active.
NOTE:
24 Hour type zones will report the restoral immediately when the
zone is secured.
Restoral on Bell Time-out. . . . . . . . . . . . . . . . . . . . . . . . . Section [380], Option [2]
AC Failure Communication Delay Time . . . . . . . . . . . . . . . . . . . . . . . Section [370]
2.3.13 Talk/Listen-in
Programming
NOTE:
The Event Buffer follows Swinger Shutdown option must be
enabled if Talk/Listen-In is used.
The NT9010 system has a Talk/Listen-In feature. This feature allows central station
operators to listen in on what is happening on the premises, and for some events
to talk to anybody present on the premises. You can program Talk/Listen-in sessions
to be triggered by zone alarms, keypad-activated Auxiliary and Panic alarms, open-
ings/closings, duress alarms, tamper alarms, or opening after alarm conditions.
For this feature to work, communications must be enabled (section [380], option
[1]), and the system must be programmed to report the event. For example, if a
reporting code for a zone is not programmed, an event in that zone will not initiate
Talk/Listen-In session. See 2.3.12 CommunicatorReporting Codes on page 47.
You can allow or disallow talk/listen-in sessions on telephone lines 1 and 3 by
changing the Talk/Listen on Phone Lines 1/3 option. You can allow or disallow
talk/listen-in sessions on telephone line 2 by changing the Talk/Listen on Phone
Line 2 option.
Zone Options
For the feature to work on a zone alarm, you must do the following:
enroll the zone on the NT9010 (see Chapter 1: Quick Set Up on page 1)
enable the talk/listen-in feature on the zone (section [802], sub-sections [50] to
[53])
program a reporting code for each zone alarm
You can have the talk/listen-in session take place on either the NT9010 control unit
or the remote sounder (if installed). In the Port Assignments sections (section
[802], sub-sections [10] to [13]), choose the unit that is closest to the zone. If you
do not assign one of the units, the talk/listen-in session will not take place over
both units.
NOTE:
All zones programmed as silent will not initiate a Talk/Listen-In
session. Only a Listen-In session can occur.
Zobrazit stránku 52
1 2 ... 48 49 50 51 52 53 54 55 56 57 58 ... 67 68

Komentáře k této Příručce

Žádné komentáře

Cables Direct B5-100Y manuels

Manuels d'utilisation et guides de l'utilisateur pour Câbles de mise en réseau Cables Direct B5-100Y.
Nous fournissons des manuels en pdf 1 Cables Direct B5-100Y à télécharger gratuitement par type de document : Fiche technique


Table des matières





Plus de produits et de manuels pour Câbles de mise en réseau Cables Direct

Modèles Type de document
URT-600-HR Fiche technique   Cables Direct URT-600-HR networking cable, 1 pages
ERT-601V Fiche technique   Cables Direct ERT-601V networking cable, 1 pages
B6-503K Fiche technique   Cables Direct B6-503K networking cable, 1 pages
B6ST-705K Fiche technique   Cables Direct B6ST-705K networking cable, 1 pages
B5-105G Fiche technique   Cables Direct B5-105G networking cable, 1 pages
URT-600P Fiche technique   Cables Direct URT-600P networking cable, 1 pages
URT-610K Fiche technique   Cables Direct URT-610K networking cable, 1 pages
XXURT-610B Fiche technique   Cables Direct XXURT-610B networking cable, 1 pages
URT-601.5G Fiche technique   Cables Direct URT-601.5G networking cable, 1 pages
URT-601W Fiche technique   Cables Direct URT-601W networking cable, 1 pages
RJEXT-10 Fiche technique   Cables Direct RJEXT-10 networking cable, 1 pages
URT-605W Fiche technique   Cables Direct URT-605W networking cable, 1 pages
B6ST-702R Fiche technique   Cables Direct B6ST-702R networking cable, 1 pages
EXT-602 Fiche technique   Cables Direct EXT-602 networking cable, 1 pages
URT-630 Fiche technique   Cables Direct URT-630 networking cable, 1 pages
ERT-601-5W Fiche technique   Cables Direct ERT-601-5W networking cable, 1 pages
B6-501B Fiche technique   Cables Direct B6-501B networking cable, 1 pages
XXURT-610R Fiche technique   Cables Direct XXURT-610R networking cable, 1 pages
EXT-605 Fiche technique   Cables Direct EXT-605 networking cable, 1 pages
B6-502R Fiche technique   Cables Direct B6-502R networking cable, 1 pages