DSC Envoy NT9010 Instalační příručka Strana 45

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 68
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 44
Section 2.3: Changing Other NT9010 Functions
41
RF Jamming Detection Zone. . . . . . . . . . . . . . . . . . . . . . . . . . . Section [807]-[093]
2.3.7 Zone Tamper/
Fault Options
By enabling Tampers/Faults Do Not Show as Open, faults and tampers for wire-
less zones will not be annunciated, and will be hidden from the end user. If the
option is disabled, faults and tampers will be annunciated.
NOTE:
Once a zone is tampered or faulted, it must be completely
restored before the trouble condition will clear.
If the All System Tampers Require Installer Reset option is enabled, any zone
faults must be reset by entering [][8][Installer’s Code] before the system can be
armed. Auto-Arming and Keyswitch arming will also be prevented in the presence
of any zone fault.
NOTE:
The Auto Arm cancellation code will not be transmitted if arming
is inhibited due to a zone fault. The Auto Arm cancellation code will be
transmitted if arming is inhibited due to Latching Tamper.
Tampers/Faults Do Not Show As Open . . . . . . . . . . . . . . . Section [013], Option [4]
All System Tampers Require Installer Reset . . . . . . . . . . . . Section [701], Option [4]
2.3.8
Communicator
Dialing
If the Communicator Disable option is selected the system will never attempt to
call central station. If the Communicator is enabled, the system will attempt to call
central station when an event occurs that has a valid reporting code programmed
(see 2.3.12 CommunicatorReporting Codes on page 47). You must also pro-
gram a valid telephone number for the communicator to work.
Communicator Call Direction Options are used to select where the system will
send different kinds of reporting codes when events occur. You can choose to have
the system send reporting codes to:
1st telephone number
2nd telephone number
These options are programmed separately for each type of reporting code.
The different types of reporting codes are:
Alarm/Restore codes
Tamper Alarm/Restore codes
Opening/Closing codes
System Maintenance Alarm/Restore codes
System Test Transmission codes
When the Force Dialing option is enabled, the system will dial out regardless of
the presence of dial tone. Each dialing attempt will follow this pattern:
a) the system picks up the telephone line and searches for dial tone for 5 seconds
b) if no dial tone is found, the system hangs up and waits for 20 seconds