Power 864SECURITY SYSTEM®TMInstallation ManualIMPORTANTThis manual contains information on limitations regarding product use and function and informat
4BackplatesThere are two different backplates available for keypadsto mount an audio station next to a keypad:PC55BP1 BackplateUse this backplate when
5Section 2: Installation and WiringThe following sections provide a complete description of how to wire and configure devices and zones.2.1 Installati
6Programmable Outputs PGM1, PGM2, PGM3, PGM4Each PGM output is designed sothat when activated by the panel,the terminal will switch to groundPGM1, PG
Installation and Wiring: 2.6 Assigning Zones to Zone Expanders7• LCD5501Z32-433 Keypad/Receiver: 260mA (max.)• PC5100 Addressable Device Interface Mod
86. Continue this procedure at each keypad until all have been assigned to the correct slot and partition.How to Program Function KeysEach of the 5 fu
Installation and Wiring: 2.10 Zone Wiring9End of Line Resistors . . . . . . . . . . . . . . . . Section [013], Option [1]Single End of Line Resistors
10NOTE: Keypad zones cannot be used for 24-hr Supervi-sory or LINKS1000 Answer.LINKS 2X50/LINKS 3000/Skyroute™Refer to the LINKSX50, LINKS3000 and Sky
11Section 3: How to ProgramThe following section of the manual describes how toenter Installer Programming and how to program the var-ious sections.NO
123.5 Viewing ProgrammingLED and LCD5501Z KeypadsAny programming section can be viewed from an LED orLCD5501Z keypad. When a programming section isent
13Section 4: Keypad CommandsUse any system keypad to enter commands, or to program the PC5020 security system. The LED keypad uses function andzone in
WARNING Please Read CarefullyNote to InstallersThis warning contains vital information. As the only individual in contact with system users, it is you
14The keypad will display the event number, partition, timeand date of the event in question. Use the [*] key to togglebetween this information and th
Keypad Commands: 4.2 [*] Commands15[*] [3] Alarm MemoryThe memory light will be on if any alarm occurred duringthe last armed period or if an alarm oc
16NOTE: If you enable the Bell Squawk on Arming/Dis-arming option (section [014], option [1]), the bell willsound arm/disarm bell squawks for all acc
Keypad Commands: 4.3 Function Keys17[*] [0] Quick ArmIf the Quick Arm Enable option is enabled the panel canbe armed by entering [*][0]. This is a use
18[14] - [*]+[7]+[2] Smoke Detector ResetThis function key provides the user with a simple methodfor activating a PGM output programmed as either opti
19Section 5: Programming SectionsThe structure of this section corresponds with the structure of the Programming Worksheets (PWS) and is intended to b
205.1 For the Record PWS Sect 1This Section identifies the client, installation date, Installer Code, hardware configuration and programming summary f
Programming Sections: 5.3 Basic Programming PWS Sect 321[005] - System TimesThis section has 9 sub-sections, 1 for each of the 8 parti-tions, and 1 fo
22[006]-[008] Special Access Codes These sections require 4 or 6 digits to be entered. [006] - Installer Code Installer Lockout Enable . . . . . . .
Programming Sections: 5.3 Basic Programming PWS Sect 32310 Latched System Event (Strobe) This output will activate when any of the selected system eve
iNew FeaturesPC5200 SupportThe PC5020 v3.1 and higher supports the new PC5200 Power Supply module. See PC5200 Power Supply Output Module, Pg 2.PC5936
24[012] - Keypad Lockout OptionsThe panel can be programmed to ‘lockout’ keypads if aseries of incorrect access code entries is made. After theNumber
Programming Sections: 5.3 Basic Programming PWS Sect 325Option Definition On/Off Description2 Bell During Auto-armON Bell Squawk During Auto-arm Enabl
26Option Definition On/Off Description7 Telephone Line Monitor ON Telephone Line Monitor enabled. The TLM function will be active and the system will
Programming Sections: 5.3 Basic Programming PWS Sect 327Option Definition On/Off Description3 Audible RF Jam Trouble BeepsON Audible RF Jam Trouble Be
28Option Definition On/Off Description2 Verbal Door Chime ON Verbal Door Chime Is Enabled. The system will verbally annunciate the zone (or programmed
Programming Sections: 5.4 Advanced Programming PWS Sect 429[020] - Keypad Zone Assignment Assigning Keypad ZonesEach keypad has a zone input to which
30ing on the programming of the Burglary VerificationOptions (Section [018], Option 6):• If the Police Code feature is being used, the first zonealarm
Programming Sections: 5.6 Communicator Programming PWS Sect631Partition 4 Zone Assignments Sections [226] to [233]Partition 5 Zone Assignments Section
32[320]-[323] - Alarm Reporting Codes, Zones 1-64The panel will transmit the Zone Alarm reporting code fora zone when the zone goes into alarm. 24-hr
Programming Sections: 5.6 Communicator Programming PWS Sect633Special Closing: a Special Closing reporting code will betransmitted if the partition(s)
PC5020 Installer Programming Quick Reference Chart SIA False Alarm ReductionMinimum requirement system for SIA-FAR Installations :• 1 PC5020 Control p
34Delinquency Code: The Delinquency reporting code issent whenever the panel is not armed within the numberof days programmed for the Delinquency Tran
Programming Sections: 5.6 Communicator Programming PWS Sect635from any telephone). It will wait for this handshake forthe duration of Post Dial Wait f
36Reporting Codes• SIA - 0 is valid in account or reporting code (not 00 in areporting code though)• ADEMCO Contact ID - 0 is not valid in account orr
Programming Sections: 5.6 Communicator Programming PWS Sect637[378] - Test Transmission Time of DayProgram the time of the test transmission in this s
386 3rd Phone Number ON Alternate Dialing Enabled (1st & 3rd). After each dialing attempt, the communicator switches between the 1st phone number
Programming Sections: 5.6 Communicator Programming PWS Sect639 [390]-[393] LINKS PreamblesDownloading can be performed through the LINKS1000cellular
40LINKS1000 Special Preamble*In some areas of North America, dialing #DAT or *DATAreduces the cellular billing increment. The LINKS1000 Spe-cial Pream
Programming Sections: 5.8 Programmable Output Programming PWS Sect 841NOTE: To perform downloading via the T-Link module,Option [1], Section 401 must
42[551]-[564] PGM Partition AssignmentThe PC5020 has an 8-bit toggle field per output that deter-mines which partitions the output is assigned to (ou
Programming Sections: 5.10 Module Programming PWS Sect 1043[703] - Delay Between Dialing AttemptsFor standard (force) dialing, the panel will go off-h
iiiTable of ContentsCommercial Burglary, Residential Fire and Burglary ApplicationsCommercial Fire ApplicationsSection 1: Introduction 11.1 About the
441. PC5400 Programming Section [801]2. PC5936 Programming Section [802]• PC5936 audio interface will allow you to connect to 16Interior (PC5921) or e
Programming Sections: 5.11 Special Installer Instructions PWS Sect 1145Placement IndicationAfter the zone is selected, the alarm contacts must beopene
46Section 6: Central & Remote Station Fire Installation Instructions6.1 IntroductionThe PC5020CF is a UL/ULC Listed panel for [1] Central &Rem
47Section 7: Fire Monitoring Zone Types This section explains all Fire monitoring zones that can be programmed on the PC5020CF and PC5700 fire module.
487.5 PC5700 Zones PC5700 WaterflowThe waterflow zones on the PC5700 are hardcoded forwaterflow operation and cannot be reprogrammed.If waterflow zone
49Section 8: Fire System Operation8.1 Manual Signal Silence Once the panel is in alarm and the alarm notificationappliances are active, entering a val
50TLM TroublesIf the PC5700 module detects a TLM Trouble on telephoneline 1 or 2, Zone 8 on the PC5700 will be violated auto-matically. The panel can
51Section 9: Listing Requirements9.1 UL Listed Commercial and Residential InstallationsThe installation requirements listed below mustbe met for the f
52Appendix A: Reporting CodesThe following tables contain Contact ID and AutomaticSIA format reporting codes. For more information onreporting code fo
53Section # Reporting Code Code Sent When...Dialer Direction*Automatic Contact ID CodesSIA Auto Reporting Codes**[344] Special Opening Opening (disarm
ivPC5020 UL Wiring DiagramNOTE: For ULC installations please refer to the ULC Wiring Diagram part #18006238 and the ULC Installation Information Shee
54Table2: Contact ID Zone Alarm/Restoral Event Codes (as per ADEMCO):Program any of these codes for zone alarms/restorals when usingthe standard (non-
55Appendix B: Wiring Diagrams B.1 PC5020CF Wiring Diagram (Ground Connection, Zone Circuits)REDBELL+AUX–ACBLK YEL GRN Z1 Z3 Z5 Z7COMCOMCOM COMZ2 Z4 Z
Wiring Diagrams56B.2 PC5020CF and PC5700 Fire Module Communications Connections B.3 Battery Lead and AC Power Lead Routing for Central Station Fire M
57B.4 Battery Lead and AC Power Routing for UL Listed Remote Fire Monitoring Systems with the PS5350 AC Output ConnectionB.5 Sensor Reset for 2-Wire S
58B.6 Sensor Reset for 4-Wire Smoke Detectors AUX ConnectionB.7 Other PGM ConnectionsSMOKEDETECTORPOWER12 VDCINOUTNOALM-OUT+-IN+BLK WHTRED GRNLATCHING
59This notice is to be framed and mounted adjacent to the control unit or the keypad at the main entrance.Fire Alarm Monitoring Operating Instructions
FCC COMPLIANCE STATEMENTCAUTION: Changes or modifications not expressly approved by Digital Security Con-trols Ltd. could void your authority to use t
PC5020 Module CompatibilityModule Compatible? CommentsClassic Escort (VPM-1) NoDLM-1 NoDLM-4 v1.x NoDLM-4 v1.0L YesDLM-7 NoEscort5580 v3.0 Yes Fully
1Section 1: Introduction1.1 About the PC5020 SystemThe PC5020 is a high end security system. It supports upto 64 zones, 8 separate partitions, and 32
2• 3 programmable telephone numbers• 1 system account number, plus 8 partition accountnumbers• Supports LINKS1000, GSM1000 cellular communica-tion, Li
Introduction: 1.4 Additional Devices3PC5936 Audio Interface ModuleThe PC5936 audio interface module provides paging,intercom, baby listen-in and door